Control Panels


MANUAL DISTRIBUTION PANEL


MODEL - P - 100 SERIES

SPECIFICATIONS


NO. OF POINTS -

INPUT             -


OUTPUT          -

ELCB              -

INDICATIONS    -


CONTACTOR    -

CONTROL        -

3

3 Phase( 440 Volts with neutral )

63 AMPS Max( Each Point )

63 AMPS/100Ma( Optional )

100 AMPS Analog Ammeter and Panel Lamps

32/40/70 AMPS Contractors

Bimetal Regulators(Sandwik)


NOTE :

4, 6, 9, 12, 24 POINTS PANEL AVAILABLE.
TAILORMADE PANEL FOR YOUR REQUIREMENTS ARE MADE.

AUTOMATIC PANEL


MODEL - LC – SERIES

SPECIFICATIONS


RANGE            -

ACCURACY       -

NO. OF POINTS  -

INPUT              -

OUTPUT           -


CONTROLS       -


ADDITIONAL     -

30 TO 1200°C

±1°C

3

220 Volts with neutral

To control a 3 point manual panel

Microprocessor Based Temperature Control

Theoritical graph output for each point(E.I.L Requirment).


NOTE :

4, 6, 9, 12, 24 POINTS PANEL AVAILABLE.
TAILORMADE PANEL FOR YOUR REQUIREMENTS ARE MADE.

AUTOMATIC DISTRIBUTION PANEL
( COMBINATION PANEL )

MODEL - CP – SERIES

SPECIFICATIONS


TWIN CONTROL -


RANGE            -

ACCURACY       -

NO. OF POINTS  -

INPUT              -


OUTPUT           -

ELCB              -

INDICATIONS     -


CONTACTOR     -

CONTROLS       -


ADDITIONAL     -

Both Manual and auto control option

30 TO 1200°C

±1°C

3

3 Phase( 440 Volts with neutral )

63 AMPS Max( Each Point )

63 AMPS/100Ma( Optional )

100 AMPS Analog Ammeter and Panel Lamps

32/40/70 AMPS Contractors

Microprocessor Based Temperature Control

Theoritical graph output for each point(E.I.L Requirment).

Digital data recording and indication to download datas on a pendrive at site(E.I.L Requirment).


NOTE :

4, 6, 9, 12, 24 POINTS PANEL AVAILABLE.
TAILORMADE PANEL FOR YOUR REQUIREMENTS ARE MADE

HEATREATMENT FURNACE BURNER CONTROL PANEL

MODEL - HT – SERIES

SPECIFICATIONS


RANGE            -

ACCURACY       -

NO. OF POINTS  -

INPUT              -


OUTPUT           -



INDICATIONS     -

CONTROLS       -


ADDITIONAL     -

0 TO 1600°C

±1°C

As per your requirments

3 Phase( 440 Volts with neutral )

RELAY for Solinoid Valves

RELAY / 4 TO 20 MA for Modulating motor

PANEL LAMPS

Microprocessor Based Temperature Control

Theoritical graph output for each point(E.I.L Requirment).


NOTE :

CONTROL FOR NUMBER OF ZONES.
TAILORMADE PANEL FOR YOUR REQUIREMENTS ARE MADE

HEATREATMENT FURNACE ELECTRIC HEATERS ( COILS ) CONTROL PANEL

MODEL - HT – SERIES

SPECIFICATIONS


RANGE            -

ACCURACY       -

NO. OF POINTS  -

INPUT              -


OUTPUT           -

INDICATIONS     -

CONTROLS       -


0 TO 1600°C

±1°C

As per your requirments

3 Phase( 440 Volts with neutral )

RELAY / CONTACTORS

PANEL LAMPS

Microprocessor Based Temperature Control


NOTE :

CONTROL FOR NUMBER OF ZONES.
TAILORMADE PANEL FOR YOUR REQUIREMENTS ARE MADEPANEL AVAILABLE

Design and Developed By Infoonet Business Solutions